品牌 | 朗盛 |
货号 | 359 |
用途 | 电子电器应用 |
牌号 | ECOBKV20FN20 |
型号 | ECOBKV20FN20 |
品名 | PA6 |
外形尺寸 | 25kg/包 |
生产企业 | LANXESS GmbH |
是否进口 | 是 |
General | ||||
Material Status
|
|
|||
Literature 1
|
|
|||
UL Yellow Card 2
|
|
|||
Search for UL Yellow Card
|
|
|||
Availability
|
|
|||
Filler / Reinforcement
|
|
|||
Additive
|
|
|||
Recycled Content
|
|
|||
Features
|
|
|||
Processing Method
|
|
Physical |
Dry
|
Conditioned
|
Unit
|
Test Method
|
Density (23°C)
|
1.31
|
--
|
g/cm3
|
ISO 1183 |
Apparent (Bulk) Density
|
0.70
|
--
|
g/cm3
|
ISO 60 |
Molding Shrinkage
|
ISO 294-4 | |||
Across Flow : 120°C, 2.00 mm 3
|
0.20
|
--
|
%
|
|
Across Flow : 260°C, 2.00 mm 4
|
0.80
|
--
|
%
|
|
Flow : 120°C, 2.00 mm 3
|
0.20
|
--
|
%
|
|
Flow : 260°C, 2.00 mm 4
|
0.80
|
--
|
%
|
Mechanical |
Dry
|
Conditioned
|
Unit
|
Test Method
|
Tensile Modulus (23°C)
|
5400
|
2300
|
MPa
|
ISO 527-1/1 |
Tensile Stress (Break, 23°C)
|
76.0
|
40.0
|
MPa
|
ISO 527-2/5 |
Tensile Strain (Break, 23°C)
|
3.0
|
27
|
%
|
ISO 527-2/5 |
Flexural Modulus 5 (23°C)
|
5300
|
2300
|
MPa
|
ISO 178/A |
Flexural Stress 5
|
ISO 178/A | |||
23°C
|
140
|
62.0
|
MPa
|
|
3.5% Strain, 23°C
|
135
|
50.0
|
MPa
|
|
Flexural Strain at Flexural Strength 6 (23°C)
|
3.8
|
7.0
|
%
|
ISO 178/A |
Impact |
Dry
|
Conditioned
|
Unit
|
Test Method
|
Charpy Notched Impact Strength
|
ISO 179/1eA | |||
-30°C
|
< 10
|
< 10
|
kJ/m2
|
|
23°C
|
< 10
|
< 10
|
kJ/m2
|
|
Charpy Unnotched Impact Strength (23°C)
|
35
|
75
|
kJ/m2
|
ISO 179/1eU |
Notched Izod Impact Strength
|
ISO 180/1A | |||
-30°C
|
< 10
|
< 10
|
kJ/m2
|
|
23°C
|
< 10
|
< 10
|
kJ/m2
|
|
Unnotched Izod Impact Strength (23°C)
|
30
|
65
|
kJ/m2
|
ISO 180/1U |
Thermal |
Dry
|
Conditioned
|
Unit
|
Test Method
|
Heat Deflection Temperature
|
||||
0.45 MPa, Unannealed
|
210
|
--
|
°C
|
ISO 75-2/B |
1.8 MPa, Unannealed
|
155
|
--
|
°C
|
ISO 75-2/A |
Vicat Softening Temperature
|
205
|
--
|
°C
|
ISO 306/B120 |
Ball Pressure Test (209°C)
|
Pass
|
--
|
|
IEC 60695-10-2 |
Melting Temperature 7
|
222
|
--
|
°C
|
ISO 11357-3 |
CLTE
|
ISO 11359-2 | |||
Flow : 23 to 55°C
|
5.0E-5
|
--
|
cm/cm/°C
|
|
Transverse : 23 to 55°C
|
8.0E-5
|
--
|
cm/cm/°C
|
Electrical |
Dry
|
Conditioned
|
Unit
|
Test Method
|
Electric Strength (23°C, 1.00 mm)
|
32
|
--
|
kV/mm
|
IEC 60243-1 |
Comparative Tracking Index (CTI) 8
|
PLC 0
|
--
|
|
UL 746A |
Comparative Tracking Index (Solution A)
|
600
|
--
|
V
|
IEC 60112 |
Flammability |
Dry
|
Conditioned
|
Unit
|
Test Method
|
Flame Rating
|
UL 94 | |||
0.75 mm
|
V-2
|
--
|
|
|
1.5 mm
|
V-2
|
--
|
|
|
Glow Wire Flammability Index
|
IEC 60695-2-12 | |||
0.75 mm
|
960
|
--
|
°C
|
|
1.5 mm
|
960
|
--
|
°C
|
|
3.0 mm
|
960
|
--
|
°C
|
|
Glow Wire Ignition Temperature
|
IEC 60695-2-13 | |||
0.75 mm
|
775
|
--
|
°C
|
|
1.5 mm
|
775
|
--
|
°C
|
|
3.0 mm
|
775
|
--
|
°C
|
|
Oxygen Index 9
|
30
|
--
|
%
|
ISO 4589-2 |
Additional Information |
Dry
|
Conditioned
|
|
|
ISO Shortname
|
ISO 16396-PA 6,G20 FR(30) (R),GF2HR,S12-050
|
--
|
|
Injection |
Dry
|
Unit
|
Test Method
|
Drying Temperature - Dry Air Dryer
|
80
|
°C
|
|
Drying Time - Dry Air Dryer
|
2.0 to 6.0
|
hr
|
|
Processing (Melt) Temp
|
250 to 270
|
°C
|
|
Mold Temperature
|
80 to 100
|
°C
|
|
Admissible Residence Time at Tmax
|
< 5.0
|
min
|
|
Residual Moisture Content
|
0.03 to 0.07
|
%
|
Karl Fisher |
Notes |